Trusted HVAC Services in Monticello, FL
For AC and heating services that go above and beyond, connect with Benson’s Heating & Air Conditioning! We have the best around in service, prices and perks such as upfront pricing and a 100% satisfaction guarantee. And best of all, you can count on us any day of the week at any time as we are available around the clock for emergencies in Monticello, FL.
Connect with us 24/7 at 850-562-3132 for fast, reliable HVAC service in Monticello, FL!
Our Heating and Air Services in Monticello, FL
Our full services include repair, replacement and maintenance on:
To learn more about our services, company and perks, please connect with us today. We invite you to also check out some of our reviews below from clients near you. They demonstrate our commitment to customer satisfaction in every job we do in the Monticello area, from the smallest fixes to the largest system overhauls.
Monticello, FL, HVAC Company FAQs
An HVAC tune-up typically includes the following in Monticello, FL:
- A cleaning of your HVAC unit
- An inspection of your HVAC unit
- A lubrication of your HVAC unit’s parts
- A replacement of your air filter
Getting your HVAC unit tuned up has many advantages because it keeps your system running smoothly and helps your energy costs stay low. To get the most out of servicing your HVAC unit, you should have it tuned up twice a year.
A home air conditioning unit recharge should cost around $350-$1,200. Some things that can impact the price of the recharge are:
- How severe the leak is
- How much refrigerant needs to be recharged
- The type of refrigerant your AC unit uses
If your leak is severe and your AC unit still uses the refrigerant R22, the cost of the repair will be on the higher end of the range. Since R22 has been discontinued, it is harder and more expensive to obtain.
To get the cleanest indoor air for your Monticello, FL home you should:
- Clean your home on a regular basis
- Open windows to let in fresh air
- Utilize exhaust fans
Another thing you can do if your indoor air quality is suffering is to get an air purifier for your home. Air purifiers can be helpful in filtering your indoor air when other methods are not as effective.
Recent Jobs and Reviews in Monticello, FL
Our Local Reviews by City
- Alligator Point, FL (32)
- Altamonte Springs, FL (1)
- Attapulgus, GA (4)
- Bainbridge, GA (12)
- Boston, GA (6)
- Bristol, FL (8)
- Cairo, FL (1)
- Cairo, GA (11)
- Carrabelle, FL (26)
- Chattahoochee, FL (13)
- Climax, GA (5)
- Crawfordville, FL (194)
- Eastpoint, FL (7)
- Greenville, FL (18)
- Havana, FL (359)
- Lamont, FL (14)
- Madison, FL (14)
- Meigs, GA (2)
- Metcalf, GA (1)
- Midway, FL (32)
- Monticello, FL (276)
- Mount Pleasant, TN (1)
- Ochlockonee Bay, FL (3)
- Panacea, FL (63)
- Panama City Beach, FL (1)
- Quincy, FL (221)
- Quincy Historic District, FL (5)
- Saint George Island, FL (6)
- Saint Teresa, FL (14)
- Seffner, FL (1)
- Sopchoppy, FL (12)
- Tallahassee, FL (12109)
- Thomasville, GA (24)
- Virgie, KY (1)
- Whigham, GA (2)
Job Locations and Reviews
AC Repair Service: A homeowner noticed their air conditioning system was struggling to maintain comfortable temperatures during the cooler fall days. We conducted a detailed inspection and discovered a clogged condenser coil and a malfunctioning thermostat. After cleaning the coil, recalibrating the thermostat, and checking for any other issues, we ensured the system was functioning efficiently. With these repairs completed, the homeowner's AC is now ready to provide balanced cooling and support heating needs during fluctuating fall temperatures, ensuring comfort throughout the season.
Furnace Repair Service: A client expressed concerns about the safety of their furnace. We performed an in-depth safety inspection and found issues, including a blocked flue pipe and a dirty smoke pipe. After resolving these problems, the furnace runs safely, giving the client peace of mind.
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: Good condition noted for both indoor and outdoor units. Indoor Unit Details: Located in the closet, identified as an air handler. Services the downstairs area. Pleated filter (2-6") replaced today. Filter size: 20x25 Honeywell. Outdoor Unit Details: Located in the back yard, identified as a heat pump. Outdoor coil is clean and was also cleaned today. Electrical Components: Blower Motor, Condenser Fan Motor, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, and Electrical Wiring tested and found to be working properly within manufacturer specifications. Inspections: Blower Wheel, Primary Drain Pan, and Electrical Wires secured and in good condition. No components found in poor condition. Temperature Readings: Return Air Temperature: 79.7°F. Supply Air Temperature: 125.7°F. Condensate Drain System: Cleared drain line and cleaned out primary pan. Additional N
Today, I arrived on site to perform maintenance on the HVAC system. * Overall equipment condition is fair. * Indoor unit located in the closet, servicing the whole home. * Pleated filter (size Sg600) was replaced today. * Condition of the indoor coil is fair. * Outdoor unit located in the back yard, with a fair condition noted. * Electrical components tested include: * Blower Motor - working properly * Heat Strip Kit - working properly * Compressor - working properly * Compressor Run Capacitor - working properly * Fan Run Capacitor - working properly * Contactor - working properly * Electrical Wiring - working properly * Electric Heat Strip Kit Safety's - working properly * No electrical components were found to be malfunctioning. * Inspected components in good condition: * Blower Wheel * Primary Drain Pan * Electrical Wires secured * No components were found in poor condition. * Carbon Monoxide test was not applicable. * Return air temperature measured at 75.0 d
Today, I arrived on site to perform a winter maintenance check on the HVAC equipment. Overall Equipment Condition: * Equipment is in good condition. Indoor Unit Details: * Located in the attic and garage. * Services the north side. * Filtration uses pleated 1" filters. * Customer has spare filters and prefers to replace them independently. * Filter size is 16x20x1. * Indoor coil is clean and in good condition. Outdoor Unit Details: * Located on the side of the house. * Outdoor coil is clean and in good condition. Electrical Components: * Blower motor, heat strip kit, compressor, compressor run capacitor, fan run capacitor, contactor, electrical wiring, and electric heat strip kit safety were tested and are functioning properly within manufacturer specifications. Inspections: * Blower wheel, primary drain pan, electrical wires secured, and secondary drain pan are in good condition and working properly. * No components were found in poor condition. Temperature Readings: * Return a
Today, I arrived on site to perform maintenance on the HVAC equipment. Overall Equipment Condition: * Good Indoor Unit Details: * Location: Attic * Type: Air Handler * Filtration: Pleated 1", replaced today * Filter Size: 18x18x1 * Condition of Indoor Coil: Good, dirty Outdoor Unit Details: * Location: Side of House * Type: Heat Pump * Condition of Outdoor Coil: Good, clean Electrical Components Tested: * Blower Motor: Working properly * Heat Strip Kit: Working properly * Condenser Fan Motor: Working properly * Compressor: Working properly * Compressor Run Capacitor: Working properly * Fan Run Capacitor: Working properly * Contactor: Working properly * Defrost Control Board: Working properly * Electrical Wiring: Working properly Inspected Components: * Good condition: Blower Wheel, Electrical Wires Secured, Primary Drain Pan, Secondary Drain Pan * Poor condition: N/A Additional Tests: * Carbon Monoxide: N/A * Return Air Temperature: 81.6°F * Supply Air Temperature: 124.0°F Conde
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in the attic as an air handler. * Services the whole home. * Filtration system includes pleated 1" filters, replaced and checked today. * Filter sizes: (1) 20x30x1, (1) 14x20x1, (1) 14x14x1. * Indoor coil condition is good and clean. Outdoor Unit Details: * Located on the side of the house as a heat pump. * Outdoor coil condition is also good and clean. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Compressor Start Capacitor * Contactor * Electrical Wiring * Defrost Control Board * Electric Heat Strip Kit Safety's System Inspections: * Inspected components in good condition: * Blower Wheel
Today I preformed a wintertime tune up on your system. Everything is working properly at this time! Thank you for choosing Bensons! Have a great day! In Monticello, FL
Today, I arrived on site to perform maintenance on the HVAC system. Overall Equipment Condition: * Condition rated as fair. Indoor Unit Details: * Type: Package Unit. * Location: Indoor. * Filtration: Checked pleated 1" filter, size 20x25x1. * Indoor Coil: Fair condition, dirty; recommend cleaning in place. Outdoor Unit Details: * Type: Package Unit. * Location: Back yard. * Outdoor Coil: Good condition, clean. Electrical Components: * Tested and inspected the following components: * Blower Motor: Working properly. * Heat Strip Kit: Working properly. * Condenser Fan Motor: Working properly. * Compressor: Working properly. * Compressor Run Capacitor: Working properly. * Fan Run Capacitor: Working properly. * Contactor: Working properly. * Defrost Control Board: Working properly. * Electrical Wiring: Working properly. Inspections: * Good condition components: * Blower Wheel. * Electrical Wires Secured. * Primary Drain Pan. * Poor condition components: N/A. T
Today, I arrived on site to perform maintenance on the HVAC equipment. Overall Equipment Condition: * Condition rated as fair. Indoor Unit Details: * Type: Package Unit. * Serves: Whole Home. * Filtration: Pleated 2-6". * Filter Size: SG600. * Indoor Coil: Good condition but dirty. Outdoor Unit Details: * Location: Back Yard. * Type: Package Unit. * Outdoor Coil: Good condition and cleaned today. Electrical Components Inspected: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring Condition of Other Components: * Good condition and functioning properly: * Blower Wheel * Electrical Wires Secured * Primary Drain Pan * No components in poor condition. Testing Results: * Carbon Monoxide: Not applicable. * Return Air Temperature: 73.0 Degrees Fahrenheit. * Supply
Today, I arrived on site to perform maintenance on the HVAC system. * Overall equipment condition is good. * Indoor unit located in the closet, identified as an air handler. * The system services the whole home. * Filtration system includes a pleated 1" filter, which was replaced today. * Filter size is 20x20x1. * Condition of the indoor coil is good. * Outdoor unit located in the back yard, identified as a heat pump. * Condition of the outdoor coil is good and was cleaned today. * Electrical components tested and inspected include: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring * All electrical components are working properly within manufacturer’s recommended specs and amperages. * Inspected components in good condition include: * Blower Wheel * Electrical Wires Secured * Primary Drain Pan * No components were found in poor condition. * No
Today, I arrived on site to perform a winter time maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in a closet as an air handler. * Services the whole home. * Filtration system features a pleated 1" filter, checked today. * Filter size is 16x25. Indoor Coil Condition: * Good and clean; brush cleaned today. Outdoor Unit Details: * Located at the back of the building as a heat pump. * Outdoor coil is also in good condition and cleaned today. Electrical Components: * All tested components are working properly within manufacturer specifications: * Blower Motor * Inducer Draft Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electric Heat Strip Kit Safety's * Electrical Wiring * No components were found to be malfunctioning. System Inspections: * Blower Wheel, Primary D
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in the garage as an air handler. * Services the whole home. * Filtration system is a pleated 1" filter; customer declined filters and will provide their own. * Filter size is 16x30. * Indoor coil is in good condition and was brush cleaned today. Outdoor Unit Details: * Located on the side of the house as a heat pump. * Outdoor coil is in good condition and was cleaned today. Electrical Components: * All tested electrical components are functioning properly within manufacturer specifications: * Blower Motor * Inducer Draft Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring * No components were found to be malfunctioning. System Inspections: * Blower Wheel, Primar
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for both indoor and outdoor units. Indoor Unit Details: * Located in a closet as an air handler. * Services the whole home. * Filtration system is a pleated 1" filter; customer declined filters and will provide their own. * Filter size is 10x10. * Indoor coil is in good condition and was brush cleaned today. Outdoor Unit Details: * Located on the side of the house as a heat pump. * Outdoor coil is in good condition and was cleaned today. Electrical Components: * All tested components are functioning properly within manufacturer specifications: * Blower Motor * Inducer Draft Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Fan Run Capacitor * Blower Run Capacitor * Compressor Run Capacitor * Contactor * Electrical Wiring System Inspections: * Blower Wheel, Primary Drain Pan, Secondary Drain Pan, and Electrical Wires are sec
**Job Summary** Today, I arrived on site to perform winter maintenance on the HVAC equipment. - **Overall Equipment Condition**: Good - **Indoor Unit**: - Location: Closet - Type: Air Handler - Filtration: Pleated 1", replaced today - Filter Size: 20x20x1 - Condition of Indoor Coil: Good, clean - **Outdoor Unit**: - Location: Back Yard - Type: Heat Pump - Condition of Outdoor Coil: Good, clean - **Electrical Components Tested**: - All components including Blower Motor, Heat Strip Kit, and Capacitors were functioning within manufacturer specs. - Warranty capacitor was out of factory range and replaced. - **Inspected Components**: - Blower Wheel, Electrical Wires, and Primary Drain Pan are in good condition. - **Carbon Monoxide Test**: Not applicable - **Temperature Readings**: - Return Air: 71.0°F - Supply Air: 120.0°F - **Condensate Drain System**: - Cleared drain line, cleaned primary pan, and tested safety switch. - **Additional Actions**: - Wor
**Job Summary** Today, I arrived on site to perform winter maintenance on the HVAC equipment. **Overall Equipment Condition** - Equipment is in good condition. **Indoor Unit Details** - Location: Closet - Type: Air Handler - Services: Whole home - Filtration: Pleated 1", checked and replaced today - Filter Size: 20x20x1 - Indoor Coil Condition: Good, clean **Outdoor Unit Details** - Location: Back Yard - Type: Heat Pump - Outdoor Coil Condition: Good, clean **Electrical Components Tested** - All tested components are functioning properly within manufacturer specifications: - Blower Motor - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Heat Strip Kit - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring **Inspections Conducted** - Components in good condition: - Blower Wheel - Electrical Wires Secured - Primary Drain Pan - No components found in poor condition. **Temperature Readings** - Retur
**Job Summary** Today, I arrived on site to perform summer maintenance on the HVAC equipment. - **Overall Equipment Condition:** Good - **Indoor Unit:** - Location: Closet - Type: Air Handler - Area Served: Upstairs/Downstairs - Filtration: Antimicrobial filter checked and replaced today - Filter Size: 20x20x1 - Indoor Coil Condition: Good, clean - **Outdoor Unit:** - Location: Side of House - Type: Heat Pump - Outdoor Coil Condition: Good, clean, cleaned today - **Electrical Components Tested:** - All components including Blower Motor, Heat Strip Kit, and Capacitors are working properly within manufacturer specs. - Capacitor replaced. - **Inspections:** - Components in good condition: Blower Wheel, Electrical Wires Secured, Primary Drain Pan - No components found in poor condition. - **Temperature Readings:** - Return Air Temperature: 71.0°F - Supply Air Temperature: 111.0°F - **Condensate Drain System:** - Cleared drain line, cleaned out primary
Job Summary Today, I arrived on site to perform winter maintenance on the HVAC equipment. Equipment Condition Overall condition: Fair Indoor unit location: Attic, Air Handler Outdoor unit location: Side of House, Heat Pump Filtration Filter type: Pleated 1" Filter size: 18x18x1 Filter condition: Checked and clean Coil Condition Indoor coil: Fair, clean Outdoor coil: Good, clean Electrical Components Tested All components tested: Blower Motor, Heat Strip Kit, Condenser Fan Motor, Compressor, Compressor Run Capacitor, Fan Run Capacitor, Compressor Start Capacitor, Contactor, Electrical Wiring All components are working properly within manufacturer’s recommended specs and amperages. Inspections Components in good condition: Blower Wheel, Secondary Drain Pan, Primary Drain Pan, Electrical Wires Secured No components found in poor condition. Temperature Readings Return Air Temperature: 76.0°F Supply Air Temperature: 100.0°F Drain System Cleared drain line and cleaned out primary pan.
Job Summary Today, I arrived on site to perform summer maintenance on the HVAC equipment. Overall Equipment Condition: Fair Indoor Unit: Location: Attic Type: Air Handler Filtration: Washable filter was cleaned today Filter Size: 20x25 Indoor Coil Condition: Fair and clean Outdoor Unit: Location: Side of House Type: Heat Pump Outdoor Coil Condition: Good and clean Electrical Components Tested: All components including Blower Motor, Heat Strip Kit, Condenser Fan Motor, Compressor, and capacitors are functioning properly within manufacturer specs. Inspections: Blower Wheel, Secondary Drain Pan, and Primary Drain Pan are in good condition. Electrical wires are secured. Temperature Readings: Return Air Temperature: 77.0°F Supply Air Temperature: 105.0°F Condensate Drain System: Cleared drain line, cleaned primary pan, and tested safety switch. Additional Actions: Wore shoe covers, dusted the thermostat, restored power to the units, and checked operation of the UV light. No issues were fou
Job Summary Today, I arrived on site to perform winter maintenance on the HVAC equipment. Equipment Condition Overall equipment condition: Fair Indoor unit location: Closet (Air Handler) Outdoor unit location: Back Yard (Heat Pump) Filtration Antimicrobial filter checked today Filter size: 16x20x1 Coil Condition Indoor coil: Fair and clean Outdoor coil: Good and clean Electrical Components Tested All components tested are functioning properly: Blower Motor Heat Strip Kit Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring Inspections Components in good condition: Blower Wheel Primary Drain Pan Electrical wires secured No components found in poor condition Temperature Readings Return air temperature: 75.0°F Supply air temperature: 100.0°F Condensate Drain System Cleared drain line Cleaned out primary pan Cleaned out condensate pump Additional Notes Wore shoe covers Dusted the thermostat Restored power t
Upon arrival found outdoor system off on locked rotor. Checked capacitor and hard start. Found hard start to be completely drained. Installed temporary hard start to keep customer cooling and tested amps. LRA is 71.3/122.1 and RLA is 10.8/20.4. System now working properly. Will consult with manufacturer as this is 2nd or 3rd hard start Thank you for your business. 9/30- replacement hard start installed via warranty for 4-5 ton systems. Paid via check
**Job Summary** Today, I arrived on site to perform maintenance on the HVAC system located in the garage, servicing the whole house. - **Overall Equipment Condition:** Fair - **Indoor Unit:** - Location: Garage - Filtration: Washable filter was cleaned today - Filter Size: 20x25x5 - Indoor Coil Condition: Fair and clean - **Outdoor Unit:** - Location: Back Yard - Outdoor Coil Condition: Fair and clean - **Electrical Components Tested:** - Blower Motor: Working properly - Condenser Fan Motor: Working properly - Compressor: Working properly - Compressor Run Capacitor: Working properly - Fan Run Capacitor: Working properly - Contactor: Working properly - Electrical Wiring: Working properly - **Inspections:** - Components in good condition: Blower Wheel, Primary Drain Pan, Electrical Wires secured - Components in poor condition: N/A - **Carbon Monoxide Test:** N/A - **Temperature Readings:** - Return Air Temperature: 80.0°F - Supply Air Temperature: 56.0
**Job Summary** Today, I arrived on site to perform summer maintenance on the HVAC equipment. **Overall Equipment Condition** - Equipment condition assessed as fair. **Indoor Unit Details** - Location: Garage - Type: Whole house system - Filtration: Pleated 1" (Customer declined filters and will provide their own) - Filter Size: 14x20x1 - Indoor Coil Condition: Fair **Outdoor Unit Details** - Location: Side of House - Outdoor Coil Condition: Fair **Electrical Components Tested** - All components tested and functioning within manufacturer specifications: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring **Inspections Conducted** - Components in good condition: - Blower Wheel - Primary Drain Pan - Electrical Wires Secured - No components found in poor condition. **Temperature Readings** - Return Air Temperature: 74.0°F - Supply Air Temperature: 54.0°F **Condensate Drain System** - C
**Job Summary** Today, I arrived on site to perform summer maintenance on the HVAC equipment. **Overall Equipment Condition** - Equipment condition rated as fair. **Indoor Unit Details** - Location: Closet - Area serviced: Upstairs - Filtration: Pleated 1" (Customer declined filters and will provide their own) - Filter size: 20x20x1 - Indoor coil condition: Fair **Outdoor Unit Details** - Location: Side of the house - Outdoor coil condition: Fair and clean **Electrical Components Tested** - All components tested and functioning within manufacturer specifications: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring **Inspected Components** - Components in good condition: - Blower Wheel - Primary Drain Pan - Electrical wires secured - Secondary Drain Pan - No components found in poor condition. **Temperature Readings** - Return air temperature: 78.0°F - Supply air temperature: 57.0°F
**Job Summary** Today, I arrived on site to perform summer maintenance on the HVAC equipment. **Overall Equipment Condition** - Condition rated as fair. **Indoor Unit** - Type: Package Unit. - Servicing the whole house. - Filtration: Checked pleated 1" antimicrobial filter; in good condition. **Indoor Coil** - Condition: Good and clean. **Outdoor Unit** - Location: Side of the house; also a package unit. - Outdoor coil condition: Good and clean. **Electrical Components** - Tested and inspected: - Blower Motor: Working properly. - Condenser Fan Motor: Working properly. - Compressor: Working properly. - Compressor Run Capacitor: Working properly. - Fan Run Capacitor: Working properly. - Contactor: Working properly. - Defrost Control Board: Working properly. - Electrical Wiring: In good condition. - No components found not working properly. **Additional Inspections** - Blower Wheel: In good condition. - Electrical wires secured. - Primary drain pan: In good conditio
Thank you so much for this great 5-star review. We really appreciate your business and helping to share the word about us.