Thomasville, GA Heating and Air Conditioning
Benson’s Heating & Air Conditioning has been providing air conditioning, heating and indoor air quality services to the residents of Thomasville, GA and the surrounding areas since 1981! Call us for your installation, repair and maintenance needs on HVAC units.
Our experience and service truly set us apart! Read our reviews and find out why your neighbors consider us to be their nearby heating and air company in Thomasville, GA.
Recent Jobs and Reviews in Thomasville, GA
Our Local Reviews by City
- Alligator Point, FL (33)
- Altamonte Springs, FL (1)
- Attapulgus, GA (4)
- Bainbridge, GA (12)
- Boston, GA (6)
- Bristol, FL (8)
- Cairo, FL (1)
- Cairo, GA (11)
- Carrabelle, FL (26)
- Chattahoochee, FL (13)
- Climax, GA (5)
- Crawfordville, FL (194)
- Eastpoint, FL (7)
- Greenville, FL (18)
- Havana, FL (364)
- Lamont, FL (14)
- Madison, FL (14)
- Meigs, GA (2)
- Metcalf, GA (1)
- Midway, FL (32)
- Monticello, FL (279)
- Mount Pleasant, TN (1)
- Ochlockonee Bay, FL (3)
- Panacea, FL (64)
- Panama City Beach, FL (1)
- Quincy, FL (222)
- Quincy Historic District, FL (5)
- Saint George Island, FL (6)
- Saint Teresa, FL (14)
- Seffner, FL (1)
- Sopchoppy, FL (12)
- Tallahassee, FL (12199)
- Thomasville, GA (24)
- Virgie, KY (1)
- Whigham, GA (2)
Job Locations and Reviews
Ej O.
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Fair Indoor Unit: * Location: Attic * Type: Air Handler * Filtration: Pleated 1", customer has spare filters and prefers to replace them independently * Filter Size: 14x24x1 * Condition of Indoor Coil: Good, brush cleaned today Outdoor Unit: * Location: Side of Building * Type: Heat Pump * Condition of Outdoor Coil: Good, clean Electrical Components: * Tested and inspected the following components, all working properly within manufacturer specs: * Blower Motor * Heat Strip Kit * Condenser Fan Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring * Defrost Control Board * No components were found to be malfunctioning System Components: * Inspected and confirmed the following components are in good condition: * Blower Wheel * Secondary Drain Pan * Primary Drain Pan * Electrical Wires Secured Air Temperatur
Thomasville, GA 31757
Ej O.
Today, I arrived on site to perform maintenance on the HVAC system. Overall equipment condition is good. Location of the indoor unit is a mini split located in the shed. Washable filters were cleaned today; filter size is for mini split units. Condition of the indoor coil is good. The outdoor unit is located on the side of the building. Outdoor coil condition is good; it was cleaned today and is clean. Electrical components tested include: Blower Motor - working properly Condenser Fan Motor - working properly Compressor - working properly Contactor - working properly Electrical Wiring - working properly No electrical components were found not working properly. Inspected components in good condition include: Blower Wheel Primary Drain Pan Electrical Wires secured No components were found in poor condition. Carbon monoxide testing was not applicable. Return air temperature measured at 71.0 degrees Fahrenheit. Supply air temperature measured at 101.0 degrees Fahrenheit. Condensate drain
Thomasville, GA 31792
Review
Junior R.
Job Summary Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: Good Indoor Unit: Package Unit, located indoors; condition of indoor coil is good and clean. Filtration: Pleated 1" filter size (8x30x1); customer declined filters and will provide their own. Outdoor Unit: Package Unit located on the side of the house; condition of outdoor coil is good and clean. Electrical Components Tested All tested components are functioning properly within manufacturer specifications: Blower Motor Condenser Fan Motor Compressor Inducer Draft Motor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring Inspections Components in good condition: Blower Wheel Primary Drain Pan Electrical Wires secured No components found in poor condition. Temperature Readings Return Air Temperature: 76.0°F Supply Air Temperature: 102.0°F Condensate Drain System Cleared drain line and cleaned out primary pan. Additional
Thomasville, GA 31792
Junior R.
Job Summary Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: Fair Indoor Unit Location: Attic, Air Handler Service Area: Whole Home Filtration: Pleated 2-6", replaced today Filter Size: 16x30x5 Indoor Coil Condition: Fair, clean Outdoor Unit Location: Back of Building, Heat Pump Outdoor Coil Condition: Good, clean Electrical Components Tested: Working Properly:Blower Motor Heat Strip Kit Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring Not Working Properly: N/A Inspections: Good Condition:Blower Wheel Secondary Drain Pan Primary Drain Pan Electrical Wires Secured Poor Condition: N/A Testing Results: Carbon Monoxide: N/A Return Air Temperature: 78.0°F Supply Air Temperature: 117.0°F Condensate Drain System: Cleared drain line Cleaned out primary pan Tested safety switch Cleaned out condensate pump Additional Notes: Wore shoe covers Dusted the th
Thomasville, GA 31792
Aidan D.
**Job Summary** Today, I arrived on site to perform summer maintenance on the HVAC equipment. **Overall Equipment Condition** - Equipment condition is good. **Indoor Unit Details** - Location: Attic - Type: Mini Split Indoor Unit - Services area: Whole home/movie room - Filtration: Pleated 1", washed today - Filter sizes: 10x10, 12x12, 14x20 **Indoor Coil Condition** - Condition: Good and clean. **Outdoor Unit Details** - Location: Side of house - Type: Mini Split Condenser - Outdoor coil condition: Good and cleaned today. **Electrical Component Testing** - All tested components are working properly within manufacturer specs: - Blower Motor - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring **Inspections** - Components in good condition: - Blower Wheel - Electrical Wires Secured - Primary Drain Pan - Secondary Drain Pan - No components found in
Thomasville, GA 31757
Ej O.
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Location, Type, and Picture of Indoor Unit: - Attic - Air Handler Area Unit Services: - Whole office Filtration: - Pleated 1" - Filter Size: 14x21x1 Condition of Indoor Coil: - Good - Clean - Brush cleaned today Location, Type, and Picture of Outdoor Unit: - Side of Building - Heat Pump Condition of Outdoor Coil: - Good - Clean Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring Tested these electrical components on your equipment and they are not working properly or not within manufacturers recommended specs and amperage's: - N/A Inspected these components on your system and they are in good co
Thomasville, GA 31757
Ej O.
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of the work I completed: Overall Equipment Condition: - Good Location, Type, and Picture of Indoor Unit: - Closet - Air Handler Area Unit Services: - Whole House Filtration: - Pleated 1" - Replaced today Filter Size and Picture of filter: - 20x25x1 Condition of Indoor Coil: - Clean - Good Location, Type, and Picture of Outdoor Unit: - Back Yard - Heat Pump Condition of Outdoor Coil: - Good - Cleaned today Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Compressor Run Capacitor - Electrical Wiring - Blower Run Capacitor - Fan Run Capacitor Tested these electrical components on your equipment and they are not working properly or not within manufacturers recommended specs and amperage's: - N/A Inspected these components on your system and they are in goo
Thomasville, GA 31792
Hunter C.
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: Good Location, Type, and Picture of Indoor Unit: Attic Air Handler Area Unit Services: The air handler is in the laundry room attic and services the entire house Filtration: Pleated 2-6" Replaced today Filter Size and Picture of filter: 16x30x5 Condition of Indoor Coil: Good Clean Location, Type, and Picture of Outdoor Unit: Back Yard Heat Pump Condition of Outdoor Coil: Good Clean Cleaned today Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: Blower Motor Condenser Fan Motor Compressor Compressor Run Capacitor Fan Run Capacitor Contactor Electrical Wiring Tested these electrical components on your equipment and they are not working properly or not within manufacturers recommended specs and amperage's: N/A Inspected these com
Thomasville, GA 31792
Ej O.
Today I replaced your thermostat,I verified all wiring is correct and ensured system cut on and off in heat and cool mode. Everything is working properly at this time. Tallahassee Fl
Thomasville, GA 31792
Review
Josh S.
I performed a winter time tune up on a Goodman package unit
Thomasville, GA 31757
Cody W.
I arrived on site and performed a winter time maintenance on your HVAC equipment. Here is a summary of the work I completed: Overall Equipment Condition: - Good Location, Type, and Picture of Indoor Unit: - Attic - Air Handler Area Unit Services: - Whole house Filtration: - Pleated 1" - Replaced today Filter Size and Picture of filter: - 20x30x1 Condition of Indoor Coil: - Good - Clean Location, Type, and Picture of Outdoor Unit: - Back Yard - Heat Pump Condition of Outdoor Coil: - Good - Clean I tested and inspected the following electrical components on your equipment, and they are working properly within the manufacturers recommended specs and amperage's: - Blower Motor - Heat Strip Kit - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring - Electric Heat Strip Kit Safety's I also inspected the following components on your system, and they are in good condition and working properly at this
Thomasville, GA 31792
Chris D.
I arrived at the home and found that the unit that heats the master bedroom not running. I preformed diagnostics on the system and found that the blower motor was the faulty part. The unit is under a 10yr P&L. I ordered the new motor and should be ready for pick up on Monday. 12/11/23 installed new motor and the system is operating properly at this time. Thank you for choosing Bensons. Thomasville Ga.
Thomasville, GA 31792
Chris D.
Installed the new motor today. Once the new motor was installed I verified the system was functioning properly. The system is now operating properly at this time. Thank you for your business today. Thomasville Georgia.
Thomasville, GA 31792
Ej O.
I performed a winter time maintenance on your HVAC equipment. Here is a summary of the work I completed: - Overall Equipment Condition: Good - Location, Type, and Picture of Indoor Unit: Attic, Air Handler - Area Unit Services: Whole building - Filtration: Pleated 1", Checked Today - Filter Size: 14x24x1 - Condition of Indoor Coil: Good, Clean - Location, Type, and Picture of Outdoor Unit: Side of Building, Heat Pump - Condition of Outdoor Coil: Good, Cleaned Today I tested and inspected the following electrical components on your equipment and found that they are working properly within the manufacturer's recommended specs and amperages: - Blower Motor - Heat Strip Kit - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring - Electric Heat Strip Kit Safety's - Defrost Control Board I also inspected the following components on your system and found that they are in good condition and working properly at this time: - Blower
Thomasville, GA 31757
Ej O.
I completed a winter time maintenance on your HVAC equipment today. Here is a summary of my findings: Overall Equipment Condition: - Good Location, Type, and Picture of Indoor Unit: - Air Handler - Closet Area Unit Services: - Whole house Filtration: - Pleated 1" - Replaced today Filter Size: - 20x25x5 Condition of Indoor Coil: - Good - Clean Location, Type, and Picture of Outdoor Unit: - Side of House - Heat Pump Condition of Outdoor Coil: - Good - Clean I tested and inspected the following electrical components on your equipment, and they are working properly within the manufacturers' recommended specs and amperages: - Blower Motor - Heat Strip Kit - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring - Defrost Control Board - Electric Heat Strip Kit Safety's I also inspected the following components on your system, and they are in good condition and working properly at this time: - Blower Wheel - Primary Drain Pan
Thomasville, GA 31792
Review
Emonte O.
Installed and programmed customer provided T9 thermostats. As well as room sensors and wifi settings. Thank you for your business.
Thomasville, GA 31757
Review
Junior R.
Today I performed a wintertime tune up on your Heat-pump, your system is working properly at this time. Thomasville, GA View findings from today’s job here - https://visionshare.xoi.io/?id=XA-D26D-8D7585827B81496E93B0CA1D15E7D148
Thomasville, GA 31792
Junior R.
Today I performed a wintertime tune up on your American standard Heat-pump, your system is working properly at this time. Thomasville GA View findings from today’s job here - https://visionshare.xoi.io/?id=XA-D26D-0E35E7955EC34C53A56681A2947FAAA0
Thomasville, GA 31792
Jacob B.
Today I performed a summer time tune up on your carrier air handler and Heat-pump, your system is working properly at this time.Tallahassee Fl View visual findings from this job here - https://visionshare.xoi.io/?id=XA-BE96-1B76604505164B48ACAAA681965AB0A1
Thomasville, GA 31792
Lee C.
Performed a duct cleaning on the system. Pulled, cleaned, and sanitized all the return and supply grills, roto brush cleaned all the duct lines, pulled cleaned and sanitized the blower assembly, cleaned and sanitized the evaporator coil in place, cleaned and sanitized the inside of the air handler, and fogged the ductwork with sanitizer. Removed the old drain line and installed a new 1” drain line from air handler all the way outside. Power cleaned the mini split at his home office.
Thomasville, GA 31757
Raymond P.
Today we performed a summer time tune up on your unit,everything is working properly at this time . However 2 units are down and estimates for repairs and replacements are in progress Thank you for your business. Tallahassee FL
Thomasville, GA 31792
Chris D.
Chemical cleaning for the condenser coil 9/8/23 today I preformed a deep clean on the condenser coil. I removed the top of the unit removed all debris from the pan and chemically cleaned the coil by backwashing. The system is now clean as it should be. Thank you for your business today.Thomasville,Georgia.
Thomasville, GA 31792
Chris D.
View visual findings from this job here - https://visionshare.xoi.io/?id=XA-EFFC-B677F249AD3345DAB4C4212688CB4A07 Today I preformed your annual maintenance. I have verified the system’s operation, cleaned and cleared the drain lines, changed the air filters, cleaned the washable filters and checked the condenser outside the systems are cooling properly at this time. Thank you for your business. Thomasville Georgia.
Thomasville, GA 31792
Chris D.
Today I worked on the downstairs master bedroom system. I also worked on the upstairs bedroom system. Mr. Kevin call in requesting service that the system were not cooling. I began diagnostics by checking the pressures on the upstairs system it was low on refrigerant I preformed a leak search and found that the evaporator coil has a leak. I added 3lbs of refrigerant and was able to get it cooling properly until we get the new coil installed. I then moved to the master bedroom unit and found it to have a bad capacitor. I have the system back up with a turbo 200 I will need to order a capacitor when I order the evaporator coil for the upstairs unit. Refrigerant for today’s repair. I also have enclosed the estimate for the repair of the new coil and capacitor replacement. Thank you for your business today. Thomasville Georgia. .
Thomasville, GA 31792
Sheldon W.
I did a summertime tuneup on your American standard and mini split everything is working properly at this time in cooling mode View visual findings from this job here - https://visionshare.xoi.io/?id=XA-B718-8AB8C9E9279E4EEEA0E046CB983A2A68